Specifications
-2015 high quality ballast HPS and MH
1000W
-UL
approved
-2 years
warranty
-extremely
efficient, saves energy
HPS/MH 1000W
BALLAST_120/240V/60Hz



ITEM NO.:15201040
1000W
ITEM NO
|
DESCRIPTION
|
NET WEIGHT(KGS)
|
GROSS WEIGHT
(KGS)
|
DIMENSION
(CM)
|
PACKING
|
15201040
|
1000W Ballast
|
13.40
|
14.40
|
42*17.5*19.5
|
1pc/carton
|
|
|
|
|
|
|
*Two year warranty
Benefits
1.Switchable
for HPS and MH bulbs
2.110v and 240v input for option
3.Simple housing
design for better cooling.
4.Available in 1000w HPS/MH lamp
5.Quiet
operation
6.Higher performance and longer life
parameter
INPUT |
OUTPUT |
Power loss
W |
Voltage In |
Current In(A) |
Power In |
Voltage Out |
Current Out(A) |
Power Out |
240.1 |
4.746 |
1118 |
261.6 |
4.597 |
984.5 |
11.94% |
INFORMATION and OPERATING
INSTRUCTIONS
These ballasts
equipped with a dual
voltage receptacle arrangement which allows the simple change between using 120
volt input power or 240 volt input power. Each system comes standard with the
120 volt power cord.
Warm up &Restart time: Once your
unit is on, the bulb will require a few minutes to reach full brightness. Also,
in the event of a momentary power interruption, the bulb will not restart
immediately.
It May Require 10-30 Minutes Cooling time Before
Restarting
Note: Some variations in the color of
the light emitted by your bulb are not unusual, especially during the first 100
hour of operation.
Unplug Fixture and Allow to Cool Before Touching or
Moving
Electrical Usage: To figure how much
amperage you unit is using simply use the following formula: Wattage + Voltage =
Amperage. The average household circuit breaker is rated at 20 amps. If the
total amperage drawn from that circuit approaches 20 amps, the circuits per
room. If you have a 1000W unit running off a 120 volt circuit, it will draw
approximately 9 amps. For the cost of electricity to run your grow light, we
recommend that you check with your local power company. Since the cost will vary
depending on the geographical area.
A 1000W
light will probably cost 10c per hour to operate. Make sure your household
circuits or fuses are in good condition and are rated at least 33% over what the
load will be (e.g. no more than 15 amp load on a 20 amp circuit). Drawing too
much current can overheat the wiring due to low voltage or insufficient amperage
in that household circuit. Extension cords should not be used with the
systems.
Bulb Replacement
Halide bulbs should be replaced after
approximately 1-1
1/2years of continuous use
(16-hour days). Sodium bulbs should be replaced after approximately 2 years of
use. At these points, light output and electrical efficiency have decreased so
that replacement is recommended. Do not run bulbs continuously beyond their
rated lives. Always unplug your system and allow bulb to cool before changing
the light bulb.
Multi-Voltage Units
All ballast units for light systems that
are 400w or higher, have multi-volt capability. This is typically only used in
larger commercial quantity size installations. For operation at input voltages
other than normal household current (120 volt), we recommend consulting a
licensed electrician or shop that specializes in electrical work for proper
wiring and plug changeover.
Follow all the reflector assembly
instructions and install the bulb into the socket before plugging in your new
connector or power supply cord. Simply plug the end from the reflector into the
receptacle in the ballast enclosure. Firmly push in on it so that it is seated
all to the base of the receptacle. If you have any questions please contact the
place of purchase. DO NOT plug anything except the designated fixture and bulb
into the proper ballast enclosure.
Some Precautions
- Do not touch the power supply when it’s
plugged in.
- Always unplug the ballast from the
outlet and allow to cool when moving or replacing parts on your
light.
- Never pull the cord to unplug the
system. Pull the plug only.
- Small pieces of glass or metal inside a
high intensity bulb are not a sign of trouble. This is common with high
intensity bulbs. Don’t be concerned unless the bulb does not
work.
- Do not try and move the ballast by
pulling the cord- use the handle.
- Do not run a bulb beyond recommended
replacement schedule- use Bulb
Replacement
- Do not look directly into the bulb during star up or
operation.
- Avoid scratching your bulb, subjecting it to under
pressure, or getting it wet when it’s wet when it’s hot, as any of these could cause it to
break.
- We recommend a lens for all light systems in areas where
water is being used.
- In the event of bulb breakage, shut off power immediately
to prevent exposure to ultraviolet energy, which may be harmful to eyes and
skin.
- Protect the bulb and ballast away from water &
moisture. Don’t mist plants unless your bulb is behind the protective
lens.
- Always make sure there is adequate air circulation (use a
fan) in your growing area. Keep the room temperature below
90*F.
- If your growing area is extremely warm or if you need to
increase air circulation, fan options are available for your light. Check with
your retailer for more information.
- Your plants should be for enough away from the bulb to
prevent heat damage. If the leaves wilt or show other signs of burn damage, the
light is too close. Usually about 2-3 feet is right for a
1000W
light. Less distance is allowable for lower wattages.
- Use caution when moving your plants from lower light
situations (window or fluorescents) to a high intensity halide or sodium. They
can get sunburned. Keep the light an extra foot away and increase the number of
hours of exposure over a couple of days.
- Always use a heavy duty three-prong
grounded
timer, rated for at least 15 amps. Many
7-day digital
timers are not rated for 1000W
lights.
- Each ballast will operate only on a specific wattage and
type of light--- do not
interchange it with any different wattage or other type of light. Interchange
only between identical units with units
unplugged.
TROUBLESHOOTING
- 1.
Check your electrical source. Make sure the unit is
plugged in properly and that the breaker is not tripped or the fuse blown. (The
ballast should hum slightly if it’s receiving
electricity.)
- 2.
Check your grounded
timer--- plug the
unit directly into your outlet.
- 3.
Unplug the unit and make sure the lamp is screw in all
the way.
- 4.
If you have another working identical unit, unplug it and
interchange bulbs to identify the faulty part.
- 5.
Make sure you have given the unit plenty of time to
restart (15—30
minutes)If it was turned
off.
Certification

Company
Information
Guangzhou
Hydrostar Ltd, established in 2000 in Guangzhou China, is one of the leading
manufacturer specializing in ballast,trimmer,reflector, air ailencer,LMUs, fan.
With more than 10 years of experience in this field, we produce not only our
mature and stable high quality products, but also develop new items to meet our
customers growing needs.
We enjoy
excellent reputation among our customers with good quality, best price and on
time delivery. Our products are popular around the world, including the USA,
Canada, Australia and Europe.




If you want to know more about our
hydroponics products,please visit our website:
http://www.ht-manufacture.com